Tank size is set by state rules, usually from the number of bedrooms, since bedrooms are a stand-in for how many people will live there. Here is what three of our launch states require, quoted from the rules themselves:
Minnesota (Minn. R. 7080.1930)
| Bedrooms | Minimum liquid capacity |
|---|---|
| 3 or fewer | 1,000 gal |
| 4–5 | 1,500 gal |
| 6–7 | 2,000 gal |
| 8–9 | 2,500 gal |
The rule adds at least 50% if there's a garbage disposal or a sewage ejector pump.
Florida (Rule 62-6.008, F.A.C.)
Florida estimates daily flow from bedrooms and floor area, then sets a minimum effective tank capacity from that flow. Homes with 1 to 3 bedrooms (up to 300 gallons a day) need at least 900 gallons. A 4-bedroom home (up to 400 gallons a day) needs 1,050 gallons. Each additional bedroom, or each additional 750 square feet, adds 60 gallons a day of estimated flow.
Georgia (DPH Onsite Sewage Manual)
Georgia requires at least 1,000 gallons for homes with 1 to 4 bedrooms, plus 250 gallons for each additional bedroom. A garbage disposal raises the requirement by 50%.
Texas (30 TAC 285.91, Table III)
Texas sizes systems from daily wastewater flow. A three-bedroom home under 2,500 square feet is rated at 300 gallons a day, or 240 with water-saving fixtures. The tank and drain field are then sized from that flow.
Use the tank size calculator to check a specific house. Your permit file at the county will show the tank that was actually installed, and that's the number to use when you get a pumping quote.
FAQ
What size septic tank does a 3-bedroom house need?
It depends on the state. Minnesota and Georgia require 1,000 gallons, and Florida requires 900.
Do I need a bigger tank with a garbage disposal?
In Minnesota and Georgia, yes: at least 50% more capacity.